MEASURING ANTENNA П6-23M
- 0.85 – 17.44 GHz
- Single channel, linear polarization
- Operating frequency range - 0.85 to 17.44 GHz
- Input wave resistance - 50 Ω
- Standing wave ratio, input (SWR) ≤ 1.7
- Signal level, orthogonal polarization - ≤ –25 dB
- Side lobe level ≤ –10 dB
- Limit of addit. relative error of effective surface ≤ ±15 %
- Overall dimensions: 936x416x320 mm
- Weight: 26.0 kg
- Operating conditions: – 50 ≤ t° ≤ + 60°С
- RH – 95 % at t° = 35°С
- Рmin.= 60 kPa (460 mm Hg)
- Optional tripod
MEASURING ANTENNA П6-61
- 26 MHz - 300 MHz
- Narrow-band full-wave antenna П6-61
- Operating frequency range: 26,0 – 300 MHz
- Wave resistance, input 50 Ohm
- Gain factor, addit. error limit- ≤ ± 1.5 dB
- Standing wave ratio, input (SWR) <= 2
- Signal level, orthogonal polarization - ≤– 20 dB
- Vertical plane polarization - 0 – 180°
- Overall dimensions, mm – 145x75x1720
- Weight: 0.7 kg
- Operating conditions: – 50 ≤ t° ≤ + 60°С
- RH – 95 % at t° = 35°С
- Рmin.= 60 kPa (460 mm Hg)
MEASURING ANTENNA П6-62
- Biconical antenna П6-62
- Operating frequency range: 300 - 1000 MHz
- Wave resistance, input 50 Ohm
- Gain factor, addit. error limit- ≤ ± 1.5 dB
- Standing wave ratio, input (SWR) ≤ 2
- Signal level, orthogonal polarization - ≤– 20 dB
- Vertical plane polarization - 0 – 180°
- Overall dimensions, mm – 400x145x150
- Weight: 1.0 kg
- Operating conditions: – 50 ≤ t° ≤ + 60°С
- RH – 95 % at t° = 35°С
- Рmin.= 60 kPa (460 mm Hg)
MEASURING ANTENNA П6-63
- Conical horn with fluoroplastic focusing lens in aperture
- Operating frequency range – 17.44 – 25.95 GHz
- Gain factor - ≥ 29 dB
- Gain factor, addit. error limit - ≤ ± 1.0 dB
- Standing wave ratio (SWR), input - ≤ 1.4
- Signal level, orthogonal polarization - ≤ – 30 dB
- Side lobe level ≤– 15 dB
- Overall dimensions, mm - 225х250
- Weight - 4,5 kg
- Operating conditions – 50 ≤ t° ≤+ 60°С
- H – 95 % at t° = 35°С
- Рmin.= 60 kPa (460 mm Hg)
MEASURING ANTENNA П6-64
Under construction.
MEASURING ANTENNA П6-65 NEW
Under construction.
MEASURING ANTENNA П6-66 NEW
В стадии наполнения
POSITIONING MOUNT ОПУ-1
В стадии наполнения
POSITIONING MOUNT ОПУ-2
В стадии наполнения